How to use this calculator
- Enter the area of the attic, loft, wall or floor you plan to insulate.
- Enter the current R-value (or RSI in metric). An uninsulated wall is about R-4; an attic with 3–4″ of old batts is about R-11.
- Enter your target R-value. US building codes call for R-38 to R-60 in attics depending on climate zone.
- Pick the insulation material, your heating degree days and the price you pay for heating energy.
- Add the installed cost per square foot or square metre to see the payback period.
How the savings are calculated
Heat flows through an assembly at a rate of 1 ÷ R (the U-value). The annual heat loss is area × U-value × heating degree days × 24 hours. We work it out for your current and target R-values; the difference, divided by the efficiency of your heating system, is the energy you save.
Required thickness is the R-value you need to add, divided by the R-value per inch of the material you choose.
Pro tips
- Seal air leaks before you insulate. Air sealing often saves as much energy as the insulation itself.
- Check for federal, state or utility rebates. In the US, the 25C tax credit has covered part of insulation costs.
- Compressing batts reduces their R-value. Don't squeeze R-19 batts into a 2×4 wall cavity.
Frequently asked questions
What is the difference between R-value and RSI?
R-value is the imperial measure of thermal resistance (ft²·°F·h/BTU). RSI is the metric equivalent (m²·K/W). RSI = R × 0.176, so R-30 is about RSI 5.3.
How do I convert a U-value to an R-value?
In metric, RSI = 1 ÷ U-value. A UK loft U-value of 0.16 W/m²K equals RSI 6.25, or about R-35.5 in imperial units.
How much attic insulation do I need?
The US Department of Energy recommends R-30 to R-49 in warm climates and R-49 to R-60 in cold climates. In the UK, 270 mm of mineral wool is the usual recommendation for lofts.
Where can I find heating degree days for my area?
Free tools such as degreedays.net and national weather services publish annual heating degree day totals for most towns. Use a base temperature of 65 °F (18 °C).
These results are estimates for planning and budgeting. Actual quantities depend on site conditions, products and workmanship. Check structural and code requirements with a licensed professional before you build.